Testing Call Router
22 Advanced Call Router Manual
Testing SQL Server Database
To test SQL server database access performance of Call Router:
1. Add a database for the SQL server.
For example, for a database “calldb” and table name “RTMCALL”,
10,000 records are added to the table.
Note: Because the data of DDR request has been hard coded, if you want
a rule match, you need to add the record to the table. The caller ID
of test request will be “1039470405.” IVR Path of test request will
be “0&9.”
To use the “SessionId” field in the table to match caller ID of the request,
you must add a record to the table and set the SessionId value to
“1039470405”. Then during match process, the matched result will be true.
2. Add a data source to “ODBC” configuration in Windows.